Workers carry respirable dust off the plant floor on their clothing into cabs, break rooms, vehicles, and homes. Mideco has engineered industrial dust control since 1950 and supplies US sites with personnel cleaning stations built around shift change and compliance obligations.

From mining and manufacturing to construction and warehousing, the responsibility of employee safety falls on your shoulders.

Enquire now

What Is a Personnel Cleaning Station?

A personnel cleaning station is a fixed point or enclosed booth where a worker removes settled dust from clothing before leaving a dusty work zone. The distinction that matters is what happens to the displaced dust.

In a handheld or wall-mounted format, released dust goes back into the air around the worker. In an enclosed walk-through cleaning booth, it is captured and filtered. Three formats are in common use:

  • Handheld air gun: operator-controlled, no built-in capture
  • Wall-mounted blow off station: fixed to structure, dust dispersed into the immediate area
  • Full walk-through cleaning booth: enclosed, automated cycle, integrated airflow capture and filtration

The right format depends on the dust type, exposure risk, and compliance program in place.

Where Blow Off Stations are Installed on Site

Personnel cleaning stations are installed at transition points between dusty and clean zones:

  • Crusher and screen house exits
  • Mine dry and change-house entries
  • Workshop, warehouse or manufacturing floor exits
  • Control room and office thresholds
  • Bus and light-vehicle boarding points
  • Locker rooms and change facilities
  • Mill and process building airlocks
  • Grain elevator and feed mill exits
  • Laboratories and sample-prep rooms
     
Enquire now

Why Open Compressed Air Blow-Down Creates a Second Problem

OSHA 29 CFR 1910.242(b) limits compressed air used for cleaning to below 30 psi, with effective chip guarding and PPE required. Many site blow-down operations run above that threshold.

Even within the limit, open blow-down resuspends settled particles directly into the breathing zone. The dust moves from clothing into surrounding air and stays airborne long enough to reach other workers in the area. Compressed air also carries a documented risk of air embolism and eye injury. A personnel blow off station or worker cleaning booth using controlled filtered airflow avoids the pressure compliance issue and the resuspension problem. A clean work booth with integrated filtration contains the removed dust within the unit.

Mideco Personnel Cleaning Stations

Maintaining Compliance and Exposure Control

A walk-through cleaning booth supports a written exposure control plan as an engineering control. OSHA 1910.1053 recognizes personnel dust removal systems within the controls hierarchy for respirable crystalline silica programs. Settled dust on clothing is also a documented secondary combustible dust hazard, so a dust removal booth or clothes cleaning booth at transition points addresses both exposure pathways at the same point. In mining, a worker cleaning booth at the mine dry entry manages dust transfer under MSHA requirements.

Choosing Between a Blow Off Station and a Walk-Through Booth

Format Best fit Safety & Compliance
Handheld air gun Spot-cleaning machinery, workbenches, tools, and hard-to-reach equipment parts. Not recommended or compliant for cleaning clothing or skin. High-pressure compressed air can force air embolisms into the bloodstream or cause severe skin and eye damage.
Wall-mounted blow off station (air blow off station) Moderate-dust zones, individual use Requires manual operation; risks dispersing to the air as it does not capture the dislodged dust unless paired with an external extraction system.
Walk-through cleaning booth High-volume personnel decontamination at the main transition points of very dusty bulk-handling, mining, cement, or chemical processing plants. Completely hands-free, highly uniform 360-degree cleaning, and captures the removed dust internally via built-in filtration rather than blowing it into the open room.

Frequently Asked Questions

A fixed point or enclosed booth where workers remove settled dust from clothing before leaving a high-dust zone. In enclosed formats, the released dust is captured and filtered inside the unit rather than dispersed into surrounding air.

An OSHA blow off station using compressed air must comply with OSHA 29 CFR 1910.242(b), limiting pressure to below 30 psi with chip guarding and PPE. Even a compliant open-air blow-off station resuspends dust into the worker’s breathing zone. Enclosed personnel cleaning booths solve this by coupling compliant air jets with active negative-pressure extraction, capturing dust the moment it leaves clothing.

A blow off booth typically uses compressed air with no integrated dust capture. A walk-through cleaning booth uses controlled airflow in an enclosed space with HEPA filtration so removed dust is contained, not dispersed.

The Bat Booth removes respirable dust from a worker’s clothing and PPE in a single 10-second cycle. By combining targeted air jets with an immediate negative-pressure extraction system, it dislodges and captures fine silica and mineral dust before it can be tracked into clean areas or re-suspended into the breathing zone.

The Bat Booth completes a cleaning cycle in 10 seconds, handling shift-change volumes without a bottleneck at zone exits.

At mine dry and change-house entries, control room thresholds, vehicle boarding points, and locker rooms as close to the dusty zone exit as practical.

Take the lead in workplace safety.

Request a quote for our advanced dust management solutions, including industry-leading dust extraction and dust collection systems.

Contact Mideco for a system that’s tailored to your facility’s operational and compliance requirements.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*
Facility Location*
How did you hear about us?*